TROUBLESHOOTING
Continued 
 WARNING: If you smell gas
•  Shut off gas supply.
•  Do not try to light any appliance.
•  Do not touch any electrical switch; do not use any phone in your building.
•  Immediately  call  your  gas  supplier  from  a  neighbor’s  phone.  Follow  the  gas 
supplier’s instructions.
•  If you cannot reach your gas supplier, call the fire department.
POSSIBLE CAUSE
1.  Gas leak. See  Warning  statement 
above 
1.  High or gusting winds
2.  Low line pressure
3.  Pilot is partially clogged
4.  Inner vent pipe leaking exhaust gasses 
into system
5.  Glass too loose and air tight gasket leaks 
in corners after usage
6.  Bad thermopile or thermocouple 
7.  Improper vent cap installation
1.  Gas leak. See  Warning  statement 
above 
2.  Control valve defective
1.  Gas leak. See  Warning  statement 
above
 
1.  Air holes at burner inlet blocked
2.  Burner flame holes blocked
3.  Improper venting or excessive blockage
4.  Excessive amounts of embers and pan 
material
OBSERVED PROBLEM
Fireplace produces unwanted odors
Fireplace shuts off in use 
Gas odor even when control knob is in OFF 
position
Gas odor during combustion
Dark residue on logs or inside of fireplace
REMEDY
1.  Locate and correct all leaks (see Check-
ing Gas Connections, page 19)
1.  Fireplace  has  been  tested  for  up  to 
40mph winds. However, extreme condi-
tions may occur. See Lighting Instruc-
tions on page 23
2.  Contact local propane/LP or natural gas  
company
3.  Clean pilot (see Cleaning and Mainte-
nance, page 27)
4.  Locate and correct all leaks (see Check-
ing Gas Connections, page 19)
5.  Tighten glass
6.  Replace faulty component 
7.  Check for proper installation and free-
dom from debris or blockage
1.  Locate and correct all leaks (see Check-
ing Gas Connections, page 19)
2.  Replace control valve
1.  Locate and correct all leaks (see Check-
ing Gas Connections, page 19)
1.  Clean out air holes at burner inlets. Pe-
riodically repeat as needed
2.  Remove blockage or replace burner
3.  Have the vent system inspected, includ-
ing the termination cap. Remove any 
restrictions or obstruction
4.  Clear excess embers until a minimum 
gap of 1/2" remains under the grate 
TROUBLESHOOTING