Mitsubishi Electronics Q170MCPU User Manual

Page of 274
 
 
 
4 - 12 
4   INSTALLATION AND WIRING 
 
4.1.4 Mounting and removal of the battery holder 
Mounting and removal procedure of the battery holder to the Motion controller is shown 
below. 
 
(1)   Handling the battery lead wire 
(a)   Precautions for handling the battery lead wire 
• For connection or removal of the battery lead wire, do it surely while 
holding a battery lead connector. 
 
PROGRAMMABLE CONTROLLER
TYPE
Q6BAT
PUSH
Motion controller
Do not hold lead wire
Battery holder
Battery lead wire
Battery lead connector
Connector for Q170MCPU side
 
 
(b)   Connection of the battery lead wire 
• For connection of a battery (Q6BAT/Q7BAT) to the Motion controller, 
connect it surely to a battery connector of Motion controller side while 
holding a battery lead connector. Be sure to insert it until it clicks. 
 
(c)   Removal of the battery lead wire 
• For removal of the battery lead wire, pull out it while holding a battery lead 
connector and a battery connector of Motion controller side. 
 
POINT 
 
(1)   Forcibly removal a connector while holding the battery lead wire will damage 
the battery connector or battery lead wire. 
 
(2)   The data (Refer to Section 6.5) of RAM built-in Motion controller are backed up 
if the battery connector is not connect correctly.