Mitsubishi Electronics AJ65BT-D75P2-S3 User Manual

Page of 666
 
 
 
12 - 23 
MELSEC-A
12   CONTROL AUXILIARY FUNCTIONS 
 
(2)   Precautions during control 
During interpolation control, speed limiting is carried out at the reference axis 
side setting value. 
(The speed limit will not function on the interpolation side.) 
 
(3)   Setting the speed limit function 
To use the "speed limit function", set the "speed limit value" in the parameters 
shown in the following table, and write them to the D75P2.  
The set details are validated after they are written to the D75P2. 
 
Setting item 
Setting 
value 
Setting details 
Factory-set 
initial value 
Pr.7  Speed limit value 
 
Set the speed limit value (max. speed during control). 
Pr.32  
JOG speed limit 
value 
 
Set the speed limit value during JOG operation (max. 
speed during control). (Note that " Pr.32  JOG speed 
limit value" shall be less than or equal to " Pr.7  
Speed limit value".) 
 
                  * Refer to section "5.2 List of parameters" for setting details. 
 
 
 
REMARK 
 Parameters are set for each axis.