Renesas R5S72621 User Manual

Page of 2152
 
Section 21   IEBus
TM
 Controller 
Page 1104 of 2108 
 
R01UH0134EJ0400  Rev. 4.00 
 
 Sep 
24, 
2014 
SH7262 Group, SH7264 Group
21.3.1
 
IEBus Control Register (IECTR) 
IECTR is used to control the operation of this module. 
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
R
R/W
R/W
R
R/W
R
R
R
Bit:
Initial value:
R/W:
-
IOL
DEE
-
RE
-
-
-
 
 
Bit Bit 
Name 
Initial 
Value 
R/W Description 
 0 
Reserved 
This bit is always read as 0. The write value should 
always be 0. 
6 IOL  0 R/W 
Input/Output 
Level 
Selects input/output pin level (polarity) for the IERxD 
and IETxD pins. 
0: Pin input/output is set to active low. (Logic 1 is low 
level and logic 0 is high level.) 
1: Pin input/output is set to active high. (Logic 1 is high 
level and logic 0 is low level.) 
DEE 
R/W 
Broadcast Receive Error Interrupt Enable 
If this bit is set to 1, a reception error interrupt occurs 
when the receive buffer is not in the receive enabled 
state during broadcast reception (when the RE bit is not 
set to 1 or the RXBSY flag is set.). At this time, the 
master address is stored in IEBus reception master 
address register 1 and 2. 
While this bit is 0, a reception error interrupt does not 
occur when the receive buffer is not in the receive 
enabled state, and the reception stops and enters the 
wait state. The master address is not saved. 
0: A broadcast receive error is not generated up to the 
control field. 
1: A broadcast receive error is generated up to the 
control field.