Renesas R5S72621 User Manual

Page of 2152
 
Section 21   IEBus
TM
 Controller 
R01UH0134EJ0400  Rev. 4.00  
 
Page 1107 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
21.3.3
 
IEBus Master Control Register (IEMCR) 
IEMCR sets the communication conditions for master communications. 
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Bit:
Initial value:
R/W:
SS
RN
CTL*
1
 
 
Bit Bit 
Name 
Initial 
Value 
R/W Description 
SS 
R/W 
Broadcast/Normal Communications Select 
Selects broadcast or normal communications for 
master communications. 
0: Broadcast communications for master 
communications 
1: Normal communications for master communications 
6 to 4 
RN 
000 
R/W 
Retransmission Counts 
Set the number of times retransmission is done when 
arbitration is lost in master communications. If 
arbitration is lost, the TXEAL flag in IETSR is set and 
transmission ends. 
000: 0 
001: 1 
010: 2 
011: 3 
100: 4 
101: 5 
110: 6 
111: 7