Section 23   CD-ROM Decoder 
Page 1258 of 2108 
 
R01UH0134EJ0400  Rev. 4.00 
 
 Sep 
24, 
2014 
SH7262 Group, SH7264 Group
23.6.6
 
Note on Stream Data Transfer (1) 
When reading of the stream data is slower than writing of the stream data, the buffer of the CD-
ROM decoder will overflow. This causes the CD-ROM decoder to be abnormally stopped. 
Caution is required in writing and reading of the stream data. Sample combinations of stream data 
transfer settings are shown below. 
Table 23.4  Sample Combinations of Stream Data Transfer Settings 
Stream Input 
Stream Output 
LW/cycle-stealing transfer by 
direct memory access controller 
(without padding) 
(1) 16-byte/cycle-stealing transfer by direct memory access 
controller (16 bytes*) 
(2) Burst transfer by direct memory access controller (16 bytes*, 
longword, word) 
LW/cycle-stealing transfer by 
direct memory access controller 
(with padding) 
(1) Cycle-stealing transfer by direct memory access controller 
(16 bytes*, longword) 
(2) Burst transfer by direct memory access controller (16 bytes*, 
longword, word) 
LW write by CPU 
(1) Cycle-stealing transfer by direct memory access controller 
(16 bytes*, longword, word) 
(2) Burst transfer by direct memory access controller (16 bytes*, 
longword, word) 
Note:  *  Set bit 25 in the DMA channel control register (CHCR_n) to 1, as well as making the 
regular settings for 16-byte transfer. 
 
23.6.7
 
Note on Stream Data Transfer (2) 
When reading the stream data, be sure to use either the direct memory access controller or the 
CPU. If both the direct memory access controller and the CPU are used for reading, the stream 