Section 7   Interrupt Controller 
 
R01UH0134EJ0400  Rev. 4.00  
 
Page 175 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
Whether IRQ interrupt requests have been detected or not can be checked by reading the IRQ7F to 
IRQ0F bits in IRQRR. Writing 0 to these bits after reading them as 1 clears the result of IRQ 
interrupt request detection. 
The IRQ interrupt exception handling sets the I3 to I0 bits in SR to the priority level of the 
accepted IRQ interrupt. 
When returning from IRQ interrupt exception service routine, execute the RTE instruction after 
confirming that the interrupt request has been cleared by the IRQ interrupt request register 
(IRQRR) so as not to accidentally receive the interrupt request again. 
7.4.4
 
PINT Interrupts 
PINT interrupts are input from pins PINT7 to PINT0. Input of the interrupt requests is enabled by 
the PINT enable bits (PINT7E to PINT0E) in the PINT interrupt enable register (PINTER). For 
the PINT7 to PINT0 interrupts, low-level or high-level detection can be selected individually for 
each pin by the PINT sense select bits (PINT7S to PINT0S) in interrupt control register 2 (ICR2). 
A single priority level in a range from 0 to 15 can be set for all PINT7 to PINT0 interrupts by bits 
15 to 12 in interrupt priority register 05 (IPR05). 
When using low-level sensing for the PINT7 to PINT0 interrupts, an interrupt request signal is 
sent to the interrupt controller while the PINT7 to PINT0 pins are low. An interrupt request signal 
is stopped being sent to the interrupt controller when the PINT7 to PINT0 pins are driven high. 
The status of the interrupt requests can be checked by reading the PINT interrupt request bits 
(PINT7R to PINT0R) in the PINT interrupt request register (PIRR). The above description also 
applies to when using high-level sensing, except for the polarity being reversed. The PINT 
interrupt exception handling sets the I3 to I0 bits in SR to the priority level of the PINT interrupt. 
When returning from IRQ interrupt exception service routine, execute the RTE instruction after 
confirming that the interrupt request has been cleared by the PINT interrupt request register 
(PIRR) so as not to accidentally receive the interrupt request again.