Renesas R5S72621 User Manual

Page of 2152
 
Section 11   Multi-Function Timer Pulse Unit 2 
 
R01UH0134EJ0400  Rev. 4.00  
 
Page 507 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
11.4
 
Operation 
11.4.1
 
Basic Functions 
Each channel has a TCNT and TGR register. TCNT performs up-counting, and is also capable of 
free-running operation, cycle counting, and external event counting. 
Each TGR can be used as an input capture register or output compare register. 
Always select functions for external pins of this module using the general I/O ports. 
(1)  Counter Operation 
When one of bits CST0 to CST4 in TSTR is set to 1, the TCNT counter for the corresponding 
channel begins counting. TCNT can operate as a free-running counter, periodic counter, for 
example. 
(a)  Example of Count Operation Setting Procedure 
Figure 11.4 shows an example of the count operation setting procedure. 
Operation selection
Select counter clock
Periodic counter
Select counter clearing
source
Select output compare
register
Set period
Free-running counter
Start count operation
<Free-running counter>
<Periodic  counter>
Start count operation
[1]
[2]
[3]
[4]
[5]
[5]
[1]  Select the counter clock 
with bits TPSC2 to TPSC0 
in TCR. At the same time, 
select the input clock edge 
with bits CKEG1 and 
CKEG0 in TCR.
[2]  For periodic counter 
operation, select the TGR 
to be used as the TCNT 
clearing source with bits 
CCLR2 to CCLR0 in TCR.
[3] Designate the TGR 
selected in [2] as an output 
compare register by means 
of TIOR.
[4]  Set the periodic counter 
cycle in the TGR selected 
in [2]. 
[5]  Set the CST bit in TSTR to 
1 to start the counter 
operation.
 
Figure 11.4   Example of Counter Operation Setting Procedure