Section 11   Multi-Function Timer Pulse Unit 2 
 
Page 514 of 2108 
 
R01UH0134EJ0400  Rev. 4.00 
 
 Sep 
24, 
2014 
SH7262 Group, SH7264 Group
Figure 11.13 shows an example of synchronous operation. 
In this example, synchronous operation and PWM mode 1 have been designated for channels 0 to 
2, TGRB_0 compare match has been set as the channel 0 counter clearing source, and 
synchronous clearing has been set for the channel 1 and 2 counter clearing source. 
Three-phase PWM waveforms are output from pins TIOC0A, TIOC1A, and TIOC2A. At this 
time, synchronous presetting, and synchronous clearing by TGRB_0 compare match, are 
performed for channel 0 to 2 TCNT counters, and the data set in TGRB_0 is used as the PWM 
cycle. 
For details of PWM modes, see section 11.4.5, PWM Modes. 
TCNT0 to TCNT2 
values
H'0000
TIOC0A
TIOC1A
TGRB_0
Synchronous clearing by TGRB_0 compare match
TGRA_2
TGRA_1
TGRB_2
TGRA_0
TGRB_1
TIOC2A
Time
 
Figure 11.13   Example of Synchronous Operation