Section 18   Serial Sound Interface 
 
R01UH0134EJ0400  Rev. 4.00  
 
Page 911 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
18.3.5
 
FIFO Control Register (SSIFCR) 
The SSIFCR register specifies the data trigger counts of the transmit and receive FIFO data 
registers, and enables or disables data resets and interrupt requests. SSIFCR can always be read or 
written by the CPU. 
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
Bit:
Initial value:
R/W:
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Bit:
Initial value:
R/W:
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
0
0
0
0
0
0
0
0
R
R
R
R
R
R
R
R
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TIE
-
TFRST
RIE
TTRG[1:0]
RTRG[1:0]
RFRST
 
 
Bit Bit 
Name 
Initial 
Value R/W Description 
31 to 8 
 All 
Reserved 
These bits are always read as 0. The write value should 
always be 0. 
7, 6 
TTRG[1:0]  00 
R/W 
Transmit Data Trigger Count 
These bits specify the transmit data count (specified 
transmit trigger count) at which the TDE flag in the 
FIFO status register (SSIFSR) is set during 
transmission. 
The TDE flag is set to 1 when the transmit data count in 
the transmit FIFO data register (SSIFTDR) is equal to 
or less than the specified trigger count shown below. 
00: 7 (1)* 
01: 6 (2)* 
10: 4 (4)* 
11: 2 (6)* 
Note: * The values in parenthesis are the number of 
empty stages in SSIFTDR at which the TDE 
flag is set.