Section 20   Controller Area Network 
 
R01UH0134EJ0400  Rev. 4.00  
 
Page 1053 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
Self Test Mode 2: 
This module generates its own Acknowledge bit, and can store its own 
messages into a reception mailbox (if required). The CRxn/CTxn (n = 0, 1) 
pins do not need to be connected to the CAN bus or any external devices, 
as the internal CTxn (n = 0, 1) is looped back to the internal CRxn (n = 0, 
1). CTxn (n = 0, 1) pin outputs only recessive bits and CRxn (n = 0, 1) pin 
is disabled. 
Write Error Counter:  TEC/REC can be written in this mode. This module can be forced to 
become an Error Passive mode by writing a value greater than 127 into the 
Error Counters. The value written into TEC is used to write into REC, so 
only the same value can be set to these registers. Similarly, this module 
can be forced to become an Error Warning by writing a value greater than 
95 into them. 
This module needs to be in Halt Mode when writing into TEC/REC 
(MCR1 must be "1" when writing to the Error Counter). Furthermore this 
test mode needs to be exited prior to leaving Halt mode.  
Error Passive Mode: 
This module can be forced to enter Error Passive mode. 
Note: The REC will not be modified by implementing this Mode. 
However, once running in Error Passive Mode, the REC will increase 
normally should errors be received. In this Mode, this module will enter 
BusOff if TEC reaches 256 (Dec). However when this mode is used this 
module will not be able to become Error Active. Consequently, at the end 
of the Bus Off recovery sequence, this module will move to Error Passive 
and not to Error Active. 
When message error occurs, IRR13 is set in all test modes.