American Water Heater (A)BCG385T500-8N User Manual

Page of 40
31
Servicing should only be performed by a Qualifi ed Service Agent
TROUBLESHOOTING
TEST 5: CALLING FOR HEAT - NO BLOWER OPERATION
Conditions:
Power on
• 
Plugs in Receptacles
• 
Red “ Call for Heat” LED - ON
• 
Blower (Draft Inducer) off
• 
Note flash code on ignition control board diagnostic LED.
Water Heater Control - Thermostat
Ignition Control Board
“Call for Heat” 
LED Indicator
Diagnostic LED
Indicator
Ground
120
Figure 24
TEST 5
IF.........
then............
Pin 1 to ground check has no voltage
•  reset control by interrupting power.  Note possible reasons for this from flashing LED code.
•  replace ignition board.
Pin 1 to ground has voltage
Proceed
Pin 3 to ground has no voltage
•  check wiring harness and plugs.       
•  replace blower.