American Water Heater (A)BCG385T500-8N User Manual
31
Servicing should only be performed by a Qualifi ed Service Agent
TROUBLESHOOTING
TEST 5: CALLING FOR HEAT - NO BLOWER OPERATION
Conditions:
Power on
•
Plugs in Receptacles
•
Red “ Call for Heat” LED - ON
•
Blower (Draft Inducer) off
•
Note flash code on ignition control board diagnostic LED.
Note flash code on ignition control board diagnostic LED.
Water Heater Control - Thermostat
Ignition Control Board
“Call for Heat”
LED Indicator
Diagnostic LED
Indicator
Ground
120
Figure 24
TEST 5
IF.........
then............
Pin 1 to ground check has no voltage
• reset control by interrupting power. Note possible reasons for this from flashing LED code.
• replace ignition board.
• replace ignition board.
Pin 1 to ground has voltage
Proceed
Pin 3 to ground has no voltage
• check wiring harness and plugs.
• replace blower.
• replace blower.