Drolet DB03505 User Manual

Page of 35
 
9
 
 
1.4 
FLOOR PROTECTOR 
 
If the stove is to be installed on top of a combustible floor, it must be guarded by a non-combustible material 
extending at least 18” (300mm) from the front and  8” (200mm) from the sides and the back of the firebox., as 
shown in Figure 1.4 below.  
Please note that a floor protection is required with the pedestal models for  spark and ash shielding, but not for 
limiting floor temperatures from the radiant heat of the stove. The stove was designed and safety tested so that 
without any protection, the floor would not overheat.    
Please refer to local building codes for suitable floor protection materials. 
 
 
 
FRONT 
 
18” (300 mm) 
 
SIDES 
 
8” (200 mm) 
 
BACK 
 
8” (200 mm) 
FIGURE 1.4  Floor protector 
 
 
C
AUTION
:    
DO NOT INSTALL IN A BEDROOM
.