Desa HDVF3018P User Manual

Page of 28
www.desatech.com
119421-01A
19
INSPECTING bURNERS 
Check pilot flame pattern and burner flame pat-
terns often.
pILOT FLAME pATTERN
Figure 24 shows a correct pilot flame pattern. Figure 
25 shows an incorrect pilot flame pattern. The incor-
rect pilot flame is not touching the thermocouple. 
This will cause the thermocouple to cool. When the 
thermocouple cools, the heater will shut down.
If pilot flame pattern is incorrect, as shown in 
Figure 25
•  turn heater off (see To Turn Off Gas to Ap-
pliance), page 18
•  see Troubleshooting, page 21
Note:
 The pilot flame on natural gas units will 
have a slight curve, but flame should be blue and 
have no yellow or orange color.
BURNER pRIMARY AIR HOLES
Air is drawn into the burner through the holes in the 
fitting at the entrance to the burner. These holes may 
become blocked with dust, lint or pet hair. Periodi-
cally inspect these holes for any blockage and clean 
as necessary. Blocked air holes will create soot.
MAIN BURNER
Periodically inspect all burner flame holes with the 
heater running. All slotted burner flame holes should 
be open with yellow flame present. All round burner 
flame holes should be open with a small blue flame 
present. Some burner flame holes may become 
blocked by debris or rust, with no flame present. If 
so, turn off heater and let cool. Remove blockage. 
Blocked burner flame holes will create soot.
Figure 24 - Correct Pilot Flame Pattern
Figure 25 - Incorrect Pilot Flame Pattern
Thermocouple
Pilot Burner
Thermocouple
Pilot Burner
CLEANING AND 
MAINTENANCE
  WARNING:  Turn  off  heater 
and let cool before cleaning.
  CAUTION:  You  must  keep 
control areas, burner and circu-
lating air passageways of heater 
clean.  Inspect  these  areas  of 
heater  before  each  use.  Have 
heater inspected yearly by a quali-
fied service person. Heater may 
need more frequent cleaning due 
to excessive lint from carpeting, 
bedding material, pet hair, etc.
  WARNING:  Failure  to  keep 
the  primary  air  opening(s)  of 
the burner(s) clean may result in 
sooting and property damage.
BURNER INjECTOR HOLDER AND 
pILOT AIR INLET HOLE
The primary air inlet holes allow the proper amount 
of air to mix with the gas. This provides a clean 
burning flame. Keep these holes clear of dust, dirt, 
lint and pet hair. Clean these air inlet holes prior to 
each heating season. Blocked air holes will create 
soot. We recommend that you clean the unit every 
three months during operation and have heater 
inspected yearly by a qualified service person.
We also recommend that you keep the burner 
tube and pilot assembly clean and free of dust and 
dirt. To clean these parts we recommend using 
compressed air no greater than 30 PSI. Your local 
computer store, hardware store or home center 
may carry compressed air in a can. You can use a 
vacuum cleaner in the blow position. If using com-
pressed air in a can, please follow the directions on 
the can. If you don’t follow directions on the can, 
you could damage the pilot assembly.