Desa HDVF3018P User Manual

Page of 28
www.desatech.com
119421-01A
20
1.  Shut off the unit, including the pilot. Allow 
the unit to cool for at least thirty minutes.
2.  Inspect burner, pilot and primary air inlet 
holes on injector holder for dust and dirt (see 
Figure 26).
3.  Blow air through the ports/slots and holes in 
the burner.
4.  Check the injector holder located at the end 
of the burner tube again. Remove any large 
particles of dust, dirt, lint or pet hair with a 
soft cloth or vacuum cleaner nozzle.
5.  Blow air into the primary air holes on the 
injector holder.
6.  In case any large clumps of dust have now been 
pushed into the burner repeat steps 3 and 4.
Clean the pilot assembly also. A yellow tip on the 
pilot flame indicates dust and dirt in the pilot as-
sembly. There is a small pilot air inlet hole about 
2" from where the pilot flame comes out of the 
pilot assembly (see Figure 27). With the unit off, 
lightly blow air through the air inlet hole. You may 
blow through a drinking straw if compressed air 
is not available.
Figure 26 - Injector Holder On Outlet 
Burner Tube
Burner 
Tube
Primary Air 
Inlet Holes
Injector Holder 
Figure 27 - Pilot Inlet Air Hole
Burner Tube
Pilot Assembly
Pilot Air 
Inlet Hole
Ports/Slots
LOGS
•  If you remove logs for cleaning, refer to Install-
ing Logs, page 15, to properly replace logs.
•  Replace log(s) if broken or chipped (dime-sized 
or larger).
MAIN BURNER
Periodically inspect all burner flame holes with 
the heater running. All slotted burner flame holes 
should be open with yellow flame present. All 
round burner flame holes should be open with a 
small blue flame present. Some burner flame holes 
may become blocked by debris or rust, with no 
flame present. If so, turn off heater and let cool. 
Remove blockage. Blocked burner flame holes 
will create soot.
CLEANING AND 
MAINTENANCE
Continued