STANDING PILOT OPERATING INSTRUCTIONS 
The fireplace is equipped with a 15 foot length of wire that can 
be used to connect the valve to a wall switch (installer provided)  
or remote control receiver.
See instructions packed with each of the following optional switches 
or controls for proper installation, operation, and maintenance.
Wall Switch, FWS-1 (optional)
On millivolt valve models, a 15' wall switch wire is included. 
Connect the two leads to a wall switch (installer supplied). See 
Figure 23.
FRBC Battery Operated Remote Control
To connect the FRBC remote to the millivolt gas valve on your 
"B-Vent"  Fireplace,  disconnect  one  wire  terminal  lead  (wall 
switch wire) from gas valve, seperate/split wall switch wire lead 
approximately 18 inches. Cut the removed lead 12 inches long 
and strip both cut ends. After stripping and baring the wire ends, 
connect the two stripped ends to the remote receiver. Reconnect 
the 1/4" insulated wire terminal (short 18" wire) to the gas valve 
wire terminal. See Figure 23.
Electric (120 volt) Operated Remote Control, FREC
Installation of the 120 Volt Receiver
Note: 
If you have a louvered model fireplace and will be installing 
the blower option, the fireplace junction box receptacle should be 
wired in accordance with Figure 28 for proper independent operation 
of the FREC remote and the optional FBB4 Blower kit.
To connect the FREC Remote to the millivolt gas valve on your 
"B"-Vent fireplace, disconnect both of the insulated wall switch 
wire terminal leads from the gas valve and discard the wall switch 
wire. Connect the two wire leads from the FREC receiver to the 
TH and TH/TP terminals on the gas valve.
Next,  attach  the  short  power  cord  to  the  remote  receiver,  then 
plug the power cord into the junction box receptacle located at 
the bottom right side of the fireplace.
The remote receiver should be located on the floor of the fireplace 
to the right of the gas valve.
Attention: The Velcro loop and hook are not necessary in this 
installation but can be used to secure remote receiver.
Refer to remote control installation and operating instructions for 
more details on remote control.
Millivolt Control
The valve regulator controls the burner pressure which should be 
checked at the pressure test point. Turn captured screw counter 
clockwise 2 or 3 turns and then place tubing to pressure gauge over 
test point (Use test point “A” closest to control knob). After taking 
pressure reading, be sure and turn captured screw clockwise firmly 
to re-seal. Do not over torque. Check for gas leaks.
Millivolt thermopile is self generating. Gas valve does not require 
24 volts or 110 volts. 
Check System Operation
Millivolt system and all individual components may be checked 
with a millivolt meter 0-1000 MV range.
It is important to use wire of a gauge proper for the length of the 
wire:
Recommended Wire Gauges
Maximum Length
Wire Gauge
1' to 10'
18
10' to 25'
16
25' to 35'
14
CAUTION: Disconnect all electrical supply to the fireplace 
prior to installing the remote control optional equipment.
OPERATING INSTRUCTIONS (CONT)