Vulcan-Hart BVD36FP52(F,L)N-1 User Manual

Page of 40
Page 19
19400-3-0406
1. STOP! Read the safety information above.
2. Set wall switch or remote to "OFF."
3. Turn  off  all  electric  power  to  the  appliance  (if  
applicable).
4. Open  bottom  louver  assembly,  or  open  valve  access 
door.
5. Push in gas control knob slightly 
and turn clockwise to 
"OFF." 
  NOTE: Knob cannot be turned 
from "PILOT" to "OFF" unless 
knob is pushed in slightly. Do not 
force.
6. Wait ten (10) minutes to clear out 
any gas. Then smell for gas, including 
near the floor. If you smell gas, STOP! 
Follow "B" in the safety information 
on reverse. If you do not smell gas, go 
to the next step.
7. Find pilot - Follow metal tube from 
gas  control.  The  pilot  is  behind  the 
burner on the right side.
8. Turn  gas  control  knob  counterclockwise  
to "PILOT."
9. Push in control knob all the way and hold in. Repeatedly 
push the Piezo Ignitor Button until the pilot is lit. Continue 
to hold the control knob in for about one (1) minute after 
the pilot is lit. Release knob, and it will pop back up. Pilot 
should remain lit. If it goes out, repeat steps 5 through 9.
 
•  If  knob  does  not  pop  up  when  released,  STOP  and  
IMMEDIATELY call a qualified service technician or 
gas supplier.
 
• If the pilot will not stay lit after several tries, turn the gas 
control knob to "OFF" and call your service technician 
or gas supplier.
10. Turn gas control knob counterclockwise to "ON."
11. Close bottom louver assembly, or close valve access door.
12.  Turn  on  all  electric  power  to  the  appliance  (if  appli-
cable).
13. Set wall switch or remote to "ON."
LIGHTING INSTRUCTIONS
FOR YOUR SAFETY, READ BEFORE LIGHTING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT 
CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE
TO TURN OFF GAS TO FIREPLACE
1. Set wall switch or remote to "OFF."
2. Turn off all electric power to the appliance if service is to 
be performed (if applicable).
3. Open  bottom  louver  assembly,  or  open  valve  access 
door.
4. Push  in  gas  control  knob  slightly  and  turn  clockwise  
 to "OFF." Do not force.
5. Close  bottom  louver  assembly,  or  close  valve  access 
door.
A. This appliance has a pilot which must be lighted by hand. 
When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area 
for gas. Be sure to smell next to the floor because some gas 
is heavier than air and will settle on the floor.
  WHAT TO DO IF YOU SMELL GAS
  • Do not try to light any appliance
  • Do not touch any electric switch.
  • Do not use any phone in your building.
  •  Immediately  call  your  gas  supplier  from  a  neighbor's 
   phone.
  • Follow the gas supplier's instructions.
  •  If  you  can  not  reach  your  gas  supplier,  call  the  fire  
   department.
C. Use only your hand to push in or turn the gas control knob. 
Never use tools. If the knob will not push in or turn by hand, 
don't try to repair it, call a qualified service technician. Force 
or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. 
Immediately call a qualified service technician to inspect 
the appliance and to replace any part of the control system 
and any gas control which has been under water.
GAS CONTROL KNOB
SHOWN IN "OFF" POSITION.
V
E
N
T
PI
LO
T
IN
ELECTRODE
PILOT
THERMOPILE
STANDING PILOT LIGHTING INSTRUCTIONS