Vulcan-Hart BVD36FP52(F,L)N-1 User Manual

Page of 40
Page 32
19400-3-0406
Attention:  Install blower assembly before connecting gas inlet 
supply line
Note:   Junction box on right side of fireplace must be pre-wired at 
time of fireplace installation for use with blower assembly. 
It is recommended that an ON/OFF wall switch be installed 
that will activate the power supply to the furnace by a 
qualified electrician.
1.  If installed, turn OFF gas supply to fireplace.
2.  If applicable, turn OFF electric supply to fireplace.
3.  Lower bottom louver on fireplace.
4.  Refer  to  page  34,  "Junction  Box  Wiring  Installation 
Instructions" to complete wiring of junction box.
Attention:  If  installed,  do  not  damage  gas  inlet  supply  line 
when blower assembly is inserted into fireplace. If 
necessary, remove gas inlet supply line.
5.  Insert  blower  assembly  into  interior,  bottom  of  fireplace. 
Position blower assembly behind gas valve, align notch on 
back of blower assembly with center screw on fireplace back 
and push blower assembly against fireplace back. The magnets 
on the back and bottom of blower assembly will sufficiently 
hold blower assembly in place.
6.  Position speed control box to the right of gas valve. Attach 
speed control box to bottom of fireplace. The magnets on 
bottom of speed control box will sufficiently hold speed control 
box in place.
7.  With base (flush face) of fan control switch facing upward, 
insert base of fan control switch under the mounting tabs on 
valve bracket. The base (flush face) of fan control switch must 
be in contact with bottom of firebox.
8.  Insert power cord plug into junction box.
9.  Close bottom louver on fireplace.
10. Installation of FBB4 optional variable speed blower assembly 
is completed.
VALVE BRACKET
FAN SWITCH
FAN KIT
SPEED CONTROL
JUNCTION BOX
SWITCH HOLDER
(TOP OF VALVE BRACKET)
SEE NOTE
OPTIONAL BLOWER
I N S TA L L AT I O N I S
I N T E N D E D F O R
LOUVERED MODELS
ONLY.
Note: Refer to wiring instructions on page 33 for 
proper operation
.
Figure 25
FBB4 OPTIONAL VARIABLE SPEED BLOWER INSTALLATION