Desa SBJ18VNA User Manual

Page of 32
www.desatech.com
114744-01B
14
  CAUTION:  Use  only  new, 
black  iron  or  steel  pipe.  Inter-
nally-tinned copper tubing may 
be used in certain areas. Check 
your  local  codes.  Use  pipe  of 
1/2" diameter or greater to allow 
proper gas volume to heater. If 
pipe is too small, undue loss of 
volume will occur.
Installation must include an equipment shutoff 
valve, union and plugged 1/8" NPT tap. Locate NPT 
tap within reach for test gauge hook up. NPT tap 
must be upstream from heater (see Figure 14).
IMPORTANT:
 Install equipment shutoff valve in 
an accessible location within 6 feet of the appli-
ance. The equipment shutoff valve is for turning 
on or shutting off the gas to the appliance.
Apply  pipe  joint  sealant  lightly  to  male  NPT 
threads. This  will  prevent  excess  sealant  from 
going into pipe. Excess sealant in pipe could result 
in clogged heater valves.
INSTALLATION
Continued 
* Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Acces-
sories, page 27.
**Minimum inlet pressure for purpose of input adjustment. 
Figure 14 - Gas Connection (Remote-Ready Models Only)
To Gas 
Control 
Valve 
3" Minimum
Sediment Trap
Propane/LP - From 
External Regulator 
(11" W.C.** To 14" 
W.C. Pressure)
Natural - From Gas 
Meter (5" W.C.** 
To 10.5" W.C. 
Pressure)
CSA Design-Certified 
Equipment Shutoff Valve 
With 1/8" NPT Tap*
Approved Flexible Gas Hose 
(if allowed by local codes)
Tee  
Pipe 
Cap
Joint 
Nipple 
For propane/LP units, the installer must supply 
an external regulator. The external regulator will 
reduce incoming gas pressure. You must reduce 
incoming gas pressure to between 11 and 14 inches 
of water. If you do not reduce incoming gas pres-
sure, heater regulator damage could occur. Install 
external regulator with the vent pointing down 
as shown in Figure 13. Pointing the vent down 
protects it from freezing rain or sleet.
Propane/LP 
Supply Tank
External 
Regulator
Figure 13 - External Regulator With Vent 
Pointing Down
Vent 
Pointing 
Down