Paradyne CSU User Manual

Page of 470
1. About the FrameSaver SLV
1-4
  
September 
2002
9128-A2-GB20-80
FrameSaver Diagnostic and SLM Feature Sets
Depending upon the model ordered, the FrameSaver unit has the basic 
FrameSaver frame relay and diagnostic capability, or it is enhanced with additional 
SLM (Service Level Management) reporting capability. These are referred to as 
feature sets, which provide different levels of intelligence for monitoring, managing, 
and reporting performance of the unit. 
The two feature sets include:
„
Basic Diagnostic Feature Set. Models with this feature set provide basic 
FrameSaver capabilities, which include:
— Leased Line mode for standard DSU installation and operation
— Device health and status
— Layer 1 (Physical) and Layer 2 (Frame Relay) performance statistics
— Basic physical testing and non-disruptive PVC diagnostics
— A troubleshooting DLCI (Data Link Connection Identifier) for service 
provider use and remote management
— Limited RMON (Remote Monitoring) functionality
— Multiplexed management PVCs
 on page 1-5 for other features and 
additional information.
„
Advanced SLM Feature Set. Models with this feature set provide all the basic 
diagnostic capability, plus advanced Service Level Management features. 
When additional SLV data is collected and the unit is accessed from an 
OpenLane SLM system, Web access to the following information is available:
— TruePut™ Technology using Frame and Data Delivery Ratios (FDR and 
DDR)
— Web browser access to all diagnostic and reporting functions
— Historical SLA (Service Level Agreement) verification and trend reports
— Real-time RMON (remote monitoring) alarms and configurable alarm 
thresholds
— Real-time and historical network performance graphs
— Multiplexed customer PVCs
 on page 1-10 for more information about 
the additional SLM capability.
If the unit does not have the SLM feature set, full SLM capability can be activated 
at any time by ordering a Feature Activation Certificate. The OpenLane SLM 
system Release 5.3 or above is required to schedule activation of advanced SLM 