Paradyne CSU User Manual

Page of 470
7. Operation and Maintenance
7-40
  
September 
2002
9128-A2-GB20-80
Line Status 
(continued)
Call Rejected – 
ISDN 
Link Name: Disabled
„
The incoming call was rejected 
because the enabled ISDN Link 
Name associated with the 
incoming Caller1 ID or local 
phone number was disabled.
The ISDN Link Name associated 
with the incoming call is 
displayed.
Link
ISDN Link Name
The selected ISDN backup link for 
which status will be displayed.
Multilink Constituent 
Link
1
ISDN Link Name
The selected multilink constituent 
link for which status will be 
displayed.
Link Operating Mode
The status of the ISDN DBM.
Disabled
2
„
The ISDN Link Profile is disabled.
Idle
2
„
An ISDN link is not currently 
needed, so there is no ISDN 
connection.
Active
„
The ISDN link is required for 
frame relay traffic and needs an 
active ISDN connection.
Call Status
The overall status of the ISDN frame 
relay link.
Not Connected – Invalid 
Link Profile
„
No calls are currently connected 
on the selected link because the 
ISDN Link Profile is incomplete.
Not Connected
„
No calls are currently connected 
on the selected link.
Connected
„
At least one call is actively 
connected and available for data 
transfer on the selected ISDN 
frame relay link (when the Most 
Recent Cause Value is 
Call 
Awarded and Being 
Delivered In Est Chnl-7
).
Connected – Incoming 
Call
1
„
An incoming call has been 
answered and is actively 
connected and available for data 
transfer on the selected multilink 
constituent link (when the Most 
Recent Cause Value is 
Call 
Awarded and Being 
Delivered In Est Chnl-7
).
Table 7-13. DBM Interface Status (2 of 3) 
Field
Status
What It Indicates
1
Only appears for a constituent frame relay link.
2
If Link Operating Mode is Disabled or Idle, the Remote Call ID, ISDN Channel, and 
Negotiated Rate fields will not appear.
3
Appears for frame relay links with only one constituent and for all constituent frame 
relay links.