Paradyne CSU User Manual

Page of 470
8. Troubleshooting
9128-A2-GB20-80
September 2002
8-7
Alarms
The following table describes the alarm conditions that will generate an SNMP trap 
for a physical interface, and the frame relay LMIs and DLCIs. These alarm 
conditions also generate Health and Status messages seen on the System and 
Test Status screen.
Main Menu
Status 
System and Test Status
Table 8-1.
Alarm Conditions (1 of 7) 
Alarm Condition
What It Indicates
What To Do
AIS at DSX-1
For the DSX-1 interface, the 
attached DTE is 
transmitting an AIS.
For the DSX-1 interface, check the 
DTE attached to the interface.
AIS at Network 1
An Alarm Indication Signal 
(AIS) is being received by 
the interface. AIS is an 
unframed, all ones signal.
For the network interface, report 
the problem to your T1 service 
provider.
CTS down to 
Port-1
 Device
The CTS control lead on the 
device’s interface is off.
Check DTR and RTS from Port-1.
„
Verify that the port is enabled.
„
Check DTR from the user data 
port.
DBM BRI Card Failed
The ISDN BRI DBM failed 
to pass the self-test.
Reset the FrameSaver unit (
Main 
Menu
Control
 Reset Device).
If the DBM fails again, contact 
your service representative.
DLCI 
nnnn  Down, 
frame relay link
The DLCI for the specified 
frame relay link is down.
Verify that the network LMI is up. If 
it is, contact your network 
provider, or your ISDN service 
provider if an ISDN Link Name is 
the link.
DTR Down from Port-1 
Device
The DTR control lead on 
the device connected to 
Port
-n is disasserted.
The DTR control lead on 
the device connected to the 
specified port is off. This 
message applies to data 
ports that act as DCEs.
Examine the attached DTE and 
cable connected to the system’s 
port.
„
Check that the port cable is 
securely attached at both ends.
„
Check the status of the 
attached equipment.
1
nnnn indicates a DLCI number of 16 through 1007.
2
frame relay link is one of the following: 
– Net1-FR1. The frame relay link specified for the network interface, Network 1.
– Port-
n. The frame relay link associated with a user data port.
– 
ISDN Link Name on a non-network ISDN DBM interface.
3
Does not apply to a TS Access Management Link DLCI.