Paradyne CSU User Manual

Page of 470
8. Troubleshooting
8-10
  
September 
2002
9128-A2-GB20-80
LOS at DSX-1
A Loss of Signal (LOS) 
condition is detected on the 
DSX-1 interface. Clears 
when the ratio of ones to 
zeros received is greater 
than or equal to 12.5%.
„
DSX-1 cable problem.
„
No signal being 
transmitted from the 
DTE.
„
Check that the DSX-1 cable is 
securely attached at both ends.
„
Check the DTE status.
LOS at Network
 1
A Loss of Signal (LOS) 
condition is detected on the 
network interface. Clears 
when the ratio of ones to 
zeros received is greater 
than or equal to 12.5%.
„
Network cable problem.
„
No signal is being 
transmitted at the far-end 
FrameSaver unit.
„
T1 facility problem.
„
Check that the network cable is 
securely attached at both ends. 
„
Check far-end FrameSaver unit 
status.
„
Contact your network provider.
Network Com Link 
Down
The communication link for 
the COM port is down and 
the COM port is configured 
for Net Link.
Check the router connected to the 
COM port.
OOF at DSX-1
An Out of Frame (OOF) 
condition is detected on the 
DSX-1 interface. 
„
Incompatible framing 
format between the DTE 
and the FrameSaver 
unit.
„
DSX-1 cabling problem.
„
Check that the framing format 
for the DSX-1 (DTE) interface 
is correct.
„
Check that the DSX-1 cable is 
securely attached at both ends.
Table 8-1.
Alarm Conditions (4 of 7) 
Alarm Condition
What It Indicates
What To Do
1
nnnn indicates a DLCI number of 16 through 1007.
2
frame relay link is one of the following: 
– Net1-FR1. The frame relay link specified for the network interface, Network 1.
– Port-
n. The frame relay link associated with a user data port.
– 
ISDN Link Name on a non-network ISDN DBM interface.
3