8. Troubleshooting
8-12
  
September 
2002
9128-A2-GB20-80
Secondary Clock 
Failed
A failure of the configured 
secondary clock source for 
the unit was detected and 
the internal clock is 
providing the timing for the 
unit.
The clock source will not 
automatically switch from 
internal until the primary 
clock source returns. 
Self-Test Failure
The unit did not pass its 
basic verification tests when 
it was powered on or reset.
„
Reset the unit.
„
Contact your service 
representative.
SLV Latency 
Exceeded, DLCI 
nnnn, 
frame relay link
The measured latency of 
SLV communication 
responses from the remote 
unit on this DLCI is 
excessive, so the DLCI has 
been declared unsuitable 
for normal multiplexed PVC 
operation (DLCI Type is set 
to Multiplexed).
Wait until the DLCI is declared 
operational again. 
If the unit has ISDN backup 
capability, this condition will 
initiate backup.
SLV Timeout, DLCI 
nnnn, frame relay 
link
An excessive number of 
SLV communication 
responses from the remote 
system have been missed 
on the specified multiplexed 
DLCI and link.
If the frame relay link is 
Net1-FR1, the timeout is on 
the network FrameRly1 
timeslot assignment.
When a hardware bypass- 
capable device has been 
detected at the other end of 
the PVC and this condition 
occurs, only user data for 
EDLCI 0 will be transmitted 
as long as the condition 
exists.
„
Verify that the network LMI is 
up. If it is, contact your network 
service provider.
„
If a DBM is present and Auto 
Backup is enabled, backup is 
initiated automatically.
Table 8-1.
Alarm Conditions (6 of 7) 
Alarm Condition
What It Indicates
What To Do
1
nnnn indicates a DLCI number of 16 through 1007.
2
frame relay link is one of the following: 
– Net1-FR1. The frame relay link specified for the network interface, Network 1.
– Port-
n. The frame relay link associated with a user data port.
– 
ISDN Link Name on a non-network ISDN DBM interface.
3
Does not apply to a TS Access Management Link DLCI.