B. SNMP MIBs and Traps, and RMON Alarm Defaults
9128-A2-GB20-80
September 2002
B-19
Rising Event Operation
If a rising threshold is crossed during the interval shown in a table (e.g., frames 
dropped by the network), the event is armed and an alarm is generated at the end 
of the interval. Only one alarm per event per interval is generated. The alarm 
condition persists until the event has been disarmed (reset).
The event is disarmed when a falling threshold has been crossed and the rising 
threshold has not been crossed during an interval, allowing the event to return to 
its original disarmed state.
Physical Interface Alarm Defaults
This alarm only applies to the FrameSaver unit’s network interface.
Table B-10. Network Physical Interface Alarm Defaults
Item
Sample
Type
1
MIB/Tag/OID
2
Interval
Event Type
Rising 
Threshold 
Default
Falling 
Threshold 
Default
Unavailable 
Seconds
D
MIB: DS1/E1 MIB (RFC 1406)
Tag: dsx1TotalUASs
OID: .1.3.6.1.2.1.10.18.9.1.5.I
900 secs 
(15 mins)
Rising
1
1
1
D = Delta. Indicates that the calculated difference between the current value and the previous value is 
contained in the MIB.
2
I in the OID = Interface ID of the frame relay link.