Paradyne CSU User Manual

Page of 470
B. SNMP MIBs and Traps, and RMON Alarm Defaults
B-20
  
September 
2002
9128-A2-GB20-80
Frame Relay Link Alarm Defaults
These alarms apply to the FrameSaver unit’s frame relay link interfaces. They are 
created during RMON initialization.
Table B-11. Frame Relay Link Alarm Defaults (1 of 2) 
Item
Sample
Type
1
MIB/Tag/OID
2
Interval
Event 
Type
Rising 
Threshold 
Default
Falling 
Threshold 
Default
Invalid Frames D
MIB: pdn_FrExt.mib (E)
Tag: devFrExtLinkRxIlFrames
OID: .1.3.6.1.4.1.1795.2.24.2.
6.9.4.7.1.18.I
900 secs 
(15 mins)
Rising
1
1
Short Frames
D
MIB: pdn_FrExt.mib (E)
Tag: devFrExtLinkRxShort
OID: .1.3.6.1.4.1.1795.2.24.2.
6.9.4.7.1.6.I
900 secs 
(15 mins)
Rising
1
1
Long Frames
D
MIB: pdn_FrExt.mib (E)
Tag: devFrExtLinkRxLong
OID: .1.3.6.1.4.1.1795.2.24.2.
6.9.4.7.1.7.I
900 secs 
(15 mins)
Rising
1
1
Rx Discards
D
MIB: pdn_FrExt.mib (E)
Tag: devFrExtLinkRxDiscards
OID: .1.3.6.1.4.1.1795.2.24.2.
6.9.4.7.1.15.I
900 secs 
(15 mins)
Rising
1
1
Tx Discards
D
MIB: pdn_FrExt.mib (E)
Tag: devFrExtLinkTxDiscards
OID: .1.3.6.1.4.1.1795.2.24.2.
6.9.4.7.1.14.I
900 secs 
(15 mins)
Rising
1
1
Rx Total 
Errors
D
MIB: pdn_FrExt.mib (E)
Tag: devFrExtLinkTotRxErrs
OID: .1.3.6.1.4.1.1795.2.24.2.
6.9.4.7.1.20.I
900 secs 
(15 mins)
Rising
1
1
1
D = Delta. Indicates that the calculated difference between the current value and the previous value is 
contained in the MIB.
2
in the OID = Interface ID of the frame relay link.