10 – Monitoring
The DM-24 contains a sophisticated monitoring sys-
tem which allows different mixes to be set up in the 
control room and the studio, as well as an integral 
talkback microphone, lineup oscillator, etc.
Control room monitoring
The control room (CR) monitoring section, which 
also includes two stereo headphone jacks, is located 
to the right of the stereo meters.
Control room outputs
As might be expected, the control-room output sig-
nals are always output from the balanced 1/4” analog 
CR (BAL) 
connectors (+4 dBu
.
However, if the digital outputs are not being used for 
any other purpose, the 
I/O OUTPUT 
screen may be 
used to assign the control room outputs to either the 
DIGITAL 1
 or
 DIGITAL 2
 sets of outputs.
From the I/O screen, use the third soft key to bring up 
the output selection screen.
Move the cursor to either of the selection boxes 
opposite the 
DIGITAL OUT1
 or 
DIGITAL OUT2
 selector.
Turn the dial until 
C.ROOM
 is shown, and press 
ENTER
.
The control room signal will now be output from the 
selected digital outputs.
NOTE
The signal is sent from both the XLR-type jack and the 
RCA jack simultaneously. The output format (AES/EBU 
or SPDIF) is set using the 
DIGITAL display FORMAT sub-
screen.
The level of the signal sent from the analog outputs is 
adjusted by the 
CR
 control.
The level of the signal sent from the headphone jacks 
(both headphone jacks together) is adjusted using the 
PHONES
 control.
Control room signal selection
There are four signal selection keys for the control 
room signal.
These are: 
STEREO
SEL 1 (AUX 1-2)
SEL 2 (D IN 
1)
SEL 3 (2 TR IN)
.
The first of these, 
STEREO
, is hard-wired. That is, 
when this option is selected, the control room outputs 
as selected above will always output the stereo buss 
signal.
The other three keys are “soft”, and may be patched 
internally to output signals other than those given as 
the defaults (in parentheses on the panel). 
The default settings may be useful when used in the 
following way, however:
When recording, aux sends 1 and 2 may be used as 
the studio cue mix, leaving aux sends 3 through 6 for 
effect use, etc. By using the 
SEL 1
 key set to the 
default 
AUX 1-2
 setting, it is therefore possible for 
the control room monitor to echo the signal sent to 
the studio.
When mixing, the mastering devices (connected to 
the stereo buss) may be digital or analog. The 
SEL 2
 
key is by default set to the first digital input (whether 
this is the XLR-type connector or the RCA jack is 
determined in the channel
 IN
 screens of the 
I/O
 setup) 
and can therefore be used for monitoring the replay 
from the digital 2-track mastering device. 
The 
SEL 3 
key is by default assigned to the analog 2-
track inputs 
. These are typically used to monitor