Tascam DM-24 User Manual

Page of 146
10 – Monitoring—Studio monitoring
74 
TASCAM DM-24 Reference Manual
the playback from an analog mastering recorder con-
nected to the DM-24.
The setting of these keys may be changed using the 
MONITOR
 screen. 
With the 
SHIFT
 indicator lit, press the 
METER/
FADER
 
[MONITOR]
 key to bring up this screen:
Use the cursor keys to move the cursor to the three 
selection key icons (
SEL 1
SEL 2
 and 
SEL 3
).
Turn the dial to select from the available options: 
AUX 
1
AUX 2
AUX 3
AUX 4
AUX 5
AUX 6
AUX1-2
AUX3-4
AUX5-6
buss 1
BUSS 2
BUSS 3
BUSS 4
BUSS 5
BUSS 
6
BUSS 7
BUSS 8
BUSS 1-2
BUSS 3-4
BUSS 5-6
BUSS 7-8
DIGITAL IN 1
DIGITAL IN 2
2-TR (ANALOG)
.
Press 
ENTER
 to confirm the choice.
NOTE
It is possible to assign the same option to more than 
one of the monitor selection keys.
The 
Follow LINK Setting
 also affects what is output 
from the control room outputs. If a mono source 
which has been stereo linked (that is, an individual 
aux or buss) is selected, and the checkbox here is 
checked, the source will be stereo linked to its “part-
ner” in the monitoring.
In this case, the odd-numbered aux or buss will be 
output from the left channel, and the even-numbered 
aux or buss from the right channel.
2-track input
Because of the analog nature of the 
2TR IN
 inputs, 
the following should be noted when monitoring from 
this source:
• Dimming when monitoring this signal is fixed at a 
level of –30dB relative to normal and cannot be 
changed.
• If the control room output is set to one of the 
DIGITAL OUTPUTS
 (
1
 or 
2
) as explained earlier 
(“Control room outputs” on page 73), it is not pos-
sible to monitor the 2-track source
• In addition, even though the studio output is an 
analog output, if the control room monitoring sys-
tem is set up to use a digital output, it is not possi-
ble to monitor the 2-track inputs through the studio 
system when echoing the control room outputs to 
the studio (see below, “Studio monitoring” on 
page 74)
.
Studio monitoring
The studio monitoring can be selected to follow the 
control room monitoring selection or to be indepen-
dent of the control room monitoring using the same 
screen as the control room setup (above).
To make the studio outputs follow the control room 
sources:
On the main monitoring page (soft key 2) move the 
cursor to the 
From CONTROL ROOM
 “radio button” and 
press 
ENTER
. When this is selected, whatever is 
selected for the control room output will also be out-
put from the studio monitoring outputs.
To set a different source for the studio, move the cur-
sor to the output select “radio button” and press 
ENTER
 to select the monitoring source displayed to 
the right of the radio button.
After this, move the cursor to the right and use the 
dial to select from the list: 
Stereo
Buss 1-2
Buss 3-4
Buss 5-6
Buss 7-8
Aux 1-2
Aux 3-4
Aux 5-6
Digital In 1
Digital In 2
2TR(Analog)
. Press 
ENTER
 to confirm the 
selection.
A pair of aux sends makes a good choice for the stu-
dio source, as these can be individually adjusted pre-
fader, and a completely separate studio mix can be 
built up in this way.