 5-11. 
TINT Gain Data 
Function 
The external control equipment changes the TINT gain data of the plasma monitor. 
 
Transmission Data 
    DFH    80H    60H    7FH    03H    DATA00    DATA01    DATA02    CKS 
 
DATA00: USER PICTURE Gain Flag     
 
01H 
 DATA01: 
TINT 
Gain 
Flag 
 
 
 
05H 
 DATA02: 
TINT 
Gain 
 
 
 
E0H: 
-32 
  
 
 
 
      * TINT Gain is from -22 (EAH) to 
 
 
FFH: -01 
    +22 (16H) only during video. 
 
 
00H: 0 
  
 
01H: 
+01 
  
 
 
  
 
20H: 
+32 
ACK 
  7FH  60H  80H  7FH  02H  DATA00  DATA01  CKS 
 
DATA00: USER PICTURE Gain Flag     
 
01H 
 DATA01: 
TINT 
Gain 
Flag 
 
 
 
05H 
 
 
 5-12. 
PICTURE MODE Select 
Function 
The external control equipment sets the picture mode of the plasma monitor. 
 
Transmission Data 
  DFH  80H  60H  0AH  01H  DATA00  CKS 
 DATA00: 
 
01H: 
NORMAL 
 
02H: THEATER1 (It cannot choose in the still picture input of a personal computer.) 
 
03H: THEATER2 (It cannot choose in the still picture input of a personal computer.) 
 04H: 
Default 
 05H: 
Bright 
ACK 
   
7FH  60H  80H  0AH  01H  DATA00  CKS 
 DATA00: 
 
01H: 
NORMAL 
 02H: 
THEATER1 
 03H: 
THEATER2 
 04H: 
Default 
 05H: 