 5-13. 
COLOR TEMP SELECT 
Function 
The external control equipment changes the COLOR TEMP of the plasma monitor. 
 
Transmission Data 
  DFH  80H  60H  00H  01H  DATA00  CKS 
 DATA00: 00H: 
low 
 01H: 
middle 
 02H: 
high 
 
03H: middle low 
ACK 
  7FH  60H  80H  00H  01H  DATA00  CKS 
 DATA00: 00H: 
low 
 01H: 
middle 
 02H: 
high 
 
03H: middle low 
 
 5-14. 
RED Gain Data 
Function 
The external control equipment changes the RED Gain Data of the plasma monitor. 
 
Transmission Data 
  DFH  80H  60H  7FH  04H  DATA00 to DATA03  CKS 
 
DATA00: USER PICTURE Gain Flag     
01H 
 
DATA01: RED Gain Flag   
 
01H 
 
DATA02: RED Gain 1(Bias) 
 
D8H : -40 
  
 
 
 
 
FFH : -01 
 
 
00H : 0 
 
 
01H : +01 
  
 
 
 
1EH : +30 
 
DATA03: RED Gain 2(Drive) 
 
D8H : -40 
  
 
 
 
 
FFH : -01 
 
 
00H : 0 
 
 
01H : +01 
  
 
 
 
1EH : +30 
ACK 
  7FH  60H  80H  7FH  02H  DATA00  DATA01  CKS 
 
DATA00: USER PICTURE Gain Flag     
01H 
 
DATA01: RED Gain Flag   
 
01H