Enterasys 6000 User Guide

Page of 420
12-8
FRX/FRM 3. 3 User G uide, Rev 04
Configuring IPX Filter Applications
IPX Filter Applications determine how filters will be used at the interface. To  review 
existing applications, press
 [C]
 at the Configure Filter Definitions and Applications 
Menu (or 
[A], [A], [E], [F], [C]
 from the
 
Main Menu). To configure an application, press 
[D]
 at the Configure Filter Definitions and Applications Menu. When prompted, enter:
Interface number:
 
0–63
. (The default is 
0
.) This identifies the virtual interface.
Filter Category
0
 = RIP, 
1
 = SAP, 
2
 = Packet, 
3
  = RIP Router. (The default is 
0
.)
Direction
i
 (inbound) or 
o
 (outbound). (The default is 
o
.)
Any other requested information, referring to Table 12-6.
Figure 12-3    Typical IPX Filter Applications Record
[A], [A],[E], [F],[D]
 from Main Menu
Up to 100 filters can be configured, displayed over 9 "pages" (screens).
When finished configuring filter definitions and applications, perform an on-line 
update to make the changes effective immediately. Press
 [E]
 at the Filter Definitions 
and Applications Configuration Menu. The changes will be sent to the software 
running on the RLPs.
Table 12-6    IPX Filter Applications Parameters
Parameter
Valid Values
Default  Value
Permit
Y/N
N
Filter "n"
0–65535
0
I PX  Filter Ap plications
*
I nterface N umber
2
*
Filter C ategory
0 R IP
*
D irection
I–In boun d
A
Permit
Y
B
Filter A pplication 1
C
Filter A pplication 2
D
Filter A pplication 3
E
Filter A pplication 4
F
Filter A pplication 5
G Filter A pplication 6
H Filter A pplication 7
I
Filter A pplication 8
0
J
Filter A pplication 9
K Filter A pplication 10
0
2
Page 2
Option: