Bosch ltc-0335-28 Installation Instruction

Page of 188
146 en | Alarms page
Bosch Video Management System
Configuration Client | V3 | 2010.07
Configuration Manual
Bosch Sicherheitssysteme GmbH
Auto-clear alarm when event state changes back to normal
Select the check box to specify that this alarm is automatically cleared when the event that 
triggers this alarm changes its state. The alarm will not be cleared automatically if it is 
accepted and unaccepted.
Show action plan
Select the check box to enable the workflow that must be processed in case of an alarm.
Resources...
Click to display the Resource Manager dialog box. Select a document with a description of 
the corresponding workflow.
Display a comment box
Select the check box to enable displaying a comment box in case of an alarm. In this comment 
box the user can type comments on the alarm.
Force the operator to process the workflow
Select the check box to force the user to process the workflow. If selected, the user cannot 
clear the alarm until he has entered a comment on the alarm.
Execute the following Client Script when alarm is accepted:
Select a Client Command Script that is executed automatically, when the user accepts an 
alarm.
Analog Monitor Group tab
1...10
In a numbered column, click a cell and select a camera from the Logical Tree. This camera will 
be displayed in the assigned monitor in case of an alarm.
Clear table
Click to remove all camera assignments to analog monitor groups.
Alarm title
Select the check box to configure that the title of the alarm is displayed on the analog 
monitors as an on-screen display.
Alarm time
Select the check box to configure that the time of the alarm is displayed on the analog 
monitors as an on-screen display.
Alarm date
Select the check box to configure that the date of the alarm is displayed on the analog 
monitors as an on-screen display.
Alarm camera name
Select the check box to configure that the name of the alarm camera is displayed on the 
analog monitors as an on-screen display.
Alarm camera number
Select the check box to configure that the number of the alarm camera is displayed on the 
analog monitors as an on-screen display.
Only on 1st monitor
Select the check box to configure that the title and the time of the alarm is displayed only on 
the first monitor of the analog monitor group as an on-screen display.