Bosch ltc-0335-28 Installation Instruction

Page of 188
168 en | Troubleshooting
Bosch Video Management System
Configuration Client | V3 | 2010.07
Configuration Manual
Bosch Sicherheitssysteme GmbH
4.
Edit the Operator Client configuration file: 
C:\<Bosch installation 
directory>\Bosch\VMS\bin\OperatorClient.exe.config 
5.
Look for a line like the following:
<add key="MicrophoneInputNr" value="2"/>
If the number for the microphone differs from the number found in the log file, change 
the number here to the number in the log file. In this example, change to number 1.
6.
Restart Operator Client.
Now the microphone is used as input source.
26.4
Reducing the number of Allegiant cameras
To reduce the number of Allegiant cameras:
1.
Start the Master Control Software.
2.
Open the Allegiant file.
3.
Click the Camera tab.
4.
Mark the cameras that are not required.
5.
On the Edit menu, click Delete.
6.
Save the file. The file size remains unchanged.
7.
Repeat the last step for monitors that you do not need. Click the Monitors tab.
8.
Import this file in Bosch Video Management System (see Section 6.3 Adding a device,