Bosch ltc-0335-28 Installation Instruction
Bosch Video Management System
Configuration examples | en
77
Bosch Sicherheitssysteme GmbH
Configuration Manual
Configuration Client | V3 | 2010.07
9.
In the Trigger Alarm list, select Always to ensure that this event always triggers an alarm.
If you want the event trigger an alarm only during a certain time span, select a schedule.
10. Click
to save the settings.
11. Click
Alarms.
12. Configure the desired alarm settings for this event.
13. Click
to save the settings and click
to activate the configuration.
14. Perform a test to ensure that the alarm is working as desired.
15.2
Adding a Bosch Allegiant input alarm
After a Bosch Allegiant device is added to Bosch Video Management System, you add Allegiant
alarm inputs.
1.
On the Device Tree, click the Allegiant device entry.
2.
Click the Inputs tab and click Add Input.
3.
Add the desired input alarms.
4.
Click Events.
5.
In the Event Tree, expand Allegiant Devices, expand Allegiant Input, and click Input
Closed or Input Opened (depends on your application).
6.
In the Trigger Alarm list, select Always to ensure that an event always triggers an alarm.
If you want the event trigger an alarm only during a certain time span, select a schedule.
7.
Click
to save the settings and click
to activate the configuration.
8.
Perform a test to ensure that the alarm is working as desired.
15.3
Adding and configuring 2 Dinion IP cameras with VRM
recording
recording
This section describes how to add 2 Dinion IP cameras for VRM recording, how to configure
different recording settings and how to configure Forensic Search for these cameras.
Prerequisite:
VRM and iSCSI devices are properly configured.
This means:
–
The VRM is added to the Device Tree.
–
An iSCSI device with configured target and LUN is assigned to this VRM.
To add the IP cameras to an existing VRM:
Main window >
Devices > Expand
1.
Right-click
and
click
Add Encoder.
The Add Encoder dialog box is displayed.
2.
Type the IP address of the IP camera and select the encoder type (Dinion IP).
Click OK.
Repeat this step for the other IP camera.