Partner Tech cd-3220 User Guide

Page of 32
 
CD7220/CD3220 CUSTOMER DISPLAY 
 
11 
5. 
SYSTEM COMMAND DETAILS   
5.1    Baud rate 
STX 05 B n ETX   
/Set baud rate and keep it with EEPROM/ 
ASCII Format 
 
STX 05 B n ETX 
Dec.  Format 
 
[02][05][66] n [03] 
Hex.  Format 
 
[02h][05h] [42h] n [03h]   30h<n<37h 
Description 
 
Change the display communication baud rate. The baud rate setting can be selected from 300 to 38400. 
The setting function will be saved to EEPROM. 
 
 
 
 
 
Baud rate 
30h 
9600 
31h 
4800 
32h 
2400 
33h 
1200 
34h 
600 
35h 
300 
36h 
38400 
37h 
19200 
 
5.2    International character set 
STX 05 S n ETX   
Change international character set 
ASCII Format 
 
STX 05 S n ETX 
Dec.  Format 
 
[02][05][83] n [03] 
Hex.  Format 
 
[02h][05h] [53h] n [03h]  30h<n<3fh 
Description 
 
Change the display international character font.  A total of 16 different character fonts to select from. 
The setting function will be saved to EEPROM. 
 
 
 
 
 
 
International font 
International font 
30h 
U.S.A 
38h 
JAPAN 
31h 
FRANCE 
39h 
NORWAY 
32h 
GERMANY 
3Ah 
DENMARK II 
33h 
U.K 
3Bh 
SLAVONIC 
34h 
DENMARK I 
3Ch 
RUSSIA 
35h 
SWEDEN 
3Dh 
Factory define 
36h 
ITALY 
3Eh 
Factory define 
37h 
SPAIN 
3Fh 
User define pattern 
 
5.3  Command type select 
STX 05 C n ETX   
Change command type 
ASCII Format 
 
STX 05 C n ETX 
Dec.  Format 
 
[02][05][67] n [03] 
Hex.  Format 
 
[02h][05h] [43h] n [03h] 30h
≦n  ≧37h 
Description 
 
This command will change the command type and initialize the display.  The display emulation mode 
is based on CD5220II/ESC POS/ADM787/ADM788/ UTC/AEDEX/EMAX mode. The setting function 
will be saved to EEPROM. 
 
 
 
 
 
 
Command type 
Command type 
30h 
DSP800 
34h 
AEDEX 
31h 
ESC/POS 
35h 
UTC/P 
32h 
ADM788 
36h 
UTC/S 
33h 
ADM787 
37h 
CD5220