Руководство Пользователя для Partner Tech cd-3220
CD7220/CD3220 CUSTOMER DISPLAY
11
5.
SYSTEM COMMAND DETAILS
5.1 Baud rate
STX 05 B n ETX
/Set baud rate and keep it with EEPROM/
ASCII Format
STX 05 B n ETX
Dec. Format
[02][05][66] n [03]
Hex. Format
[02h][05h] [42h] n [03h] 30h<n<37h
Description
Change the display communication baud rate. The baud rate setting can be selected from 300 to 38400.
The setting function will be saved to EEPROM.
The setting function will be saved to EEPROM.
N
Baud rate
30h
9600
31h
4800
32h
2400
33h
1200
34h
600
35h
300
36h
38400
37h
19200
5.2 International character set
STX 05 S n ETX
Change international character set
ASCII Format
STX 05 S n ETX
Dec. Format
[02][05][83] n [03]
Hex. Format
[02h][05h] [53h] n [03h] 30h<n<3fh
Description
Change the display international character font. A total of 16 different character fonts to select from.
The setting function will be saved to EEPROM.
The setting function will be saved to EEPROM.
n
International font
n
International font
30h
U.S.A
38h
JAPAN
31h
FRANCE
39h
NORWAY
32h
GERMANY
3Ah
DENMARK II
33h
U.K
3Bh
SLAVONIC
34h
DENMARK I
3Ch
RUSSIA
35h
SWEDEN
3Dh
Factory define
36h
ITALY
3Eh
Factory define
37h
SPAIN
3Fh
User define pattern
5.3 Command type select
STX 05 C n ETX
Change command type
ASCII Format
STX 05 C n ETX
Dec. Format
[02][05][67] n [03]
Hex. Format
[02h][05h] [43h] n [03h] 30h
≦n ≧37h
Description
This command will change the command type and initialize the display. The display emulation mode
is based on CD5220II/ESC POS/ADM787/ADM788/ UTC/AEDEX/EMAX mode. The setting function
will be saved to EEPROM.
is based on CD5220II/ESC POS/ADM787/ADM788/ UTC/AEDEX/EMAX mode. The setting function
will be saved to EEPROM.
n
Command type
n
Command type
30h
DSP800
34h
AEDEX
31h
ESC/POS
35h
UTC/P
32h
ADM788
36h
UTC/S
33h
ADM787
37h
CD5220