Allied Telesis AT-CV5000 AT-CV5000-50 Data Sheet
Product codes
AT-CV5000-50
Technical Specifications
Status Indicators
LED
State
Description
RDY (For future use)
Green
The module installed in
the rear expansion slot has
passed diagnostics and is
ready.
the rear expansion slot has
passed diagnostics and is
ready.
Off
The module installed in
the rear expansion slot has
failed diagnostics and is
not ready, or is not
installed.
the rear expansion slot has
failed diagnostics and is
not ready, or is not
installed.
MSTR (for future use)
Green
This AT-CV5000 chassis is
acting as a stacking master
(via a module installed in
the rear expansion slot).
acting as a stacking master
(via a module installed in
the rear expansion slot).
Off
This AT-CV5000 chassis is
not a stacking master.
not a stacking master.
FLT (for future use)
Green
The module installed in
the rear expansion slot has
experienced fault condition,
or is not installed.
the rear expansion slot has
experienced fault condition,
or is not installed.
Off
The module installed in
the rear expansion slot has
reported no fault
condition.
the rear expansion slot has
reported no fault
condition.
PS-A
Green
Power supply in slot A is
operating normally.
operating normally.
Off
Power supply in slot A is
OFF, not present, or has
failed.
OFF, not present, or has
failed.
PS-B
Green
Power supply in slot B is
operating normally.
operating normally.
Off
Power supply in slot B is
OFF, not present, or has
failed.
OFF, not present, or has
failed.
FAN-A
Green
Fan module in fan tray
slot A is operating
normally.
slot A is operating
normally.
Off
Fan module in fan tray
slot A is OFF, not present,
or has failed.
slot A is OFF, not present,
or has failed.
FAN-B
Green
Fan module in fan tray
slot B is operating
normally.
slot B is operating
normally.
Off
Fan module in fan tray
slot B is OFF, not present,
or has failed.
slot B is OFF, not present,
or has failed.
Connectors
The front panel features an RS232 (DB9) connector,
which will be used to provide connectivity to a rear
mounted expansion card in the future.
which will be used to provide connectivity to a rear
mounted expansion card in the future.
Physical Specifications
Dimensions:
34.25cm x 44.05cm x 8.68cm
(W x D x H)
(13.49” x 17.35” x 3.42”)
Weight:
7.5kg (16.6lbs) w/o P/S
Power Characteristics
AC input voltage:
90 ~ 240V AC 47/63Hz
AC input current:
90-120V AC (3.6A)
200-240V AC (1.57A)
200-240V AC (1.57A)
Environmental Specifications
Maximum operating
0°C to 40°C
temperature:
(32°F to 104°F)
Maximum storage
-25°C to 70°C
temperature:
(-13°F to 158°F)
Operating and
Up to 3,048 meters
storage altitude:
(10,000 feet)
Relative humidity
5% to 90% non-condensing
operating:
Relative humidity storage: 5% to 95% non-condensing
Predicted MTBF (Telcordia SR332): 64,000 hrs
Standards
EMI part 15:
FCC class A, EN55022 class A, VCCI class A, C-Tick, CE
Immunity:
EN55024
Safety:
UL60950-1 (cULUS), EN60950-1 (TUV)
Ordering Information
AT-CV5000-00
18-slot AC chassis with no power supply
AT-PWR14
AC redundant power module for AT-CV5000 chassis
Associated Products
AT-CVFAN
Replacement fan module for AT-CV5000 chassis
AT-CV5M01
SNMP management module for AT-CV5000 chassis
AT-CV1000-xx
Single slot Converteon chassis
AT-CV1203-xx
Two slot Converteon chassis
AT-CV5000
| 18 Slot Converteon Chassis
USA Headquarters
|
19800 North Creek Parkway
|
Suite 200
|
Bothell
|
WA 98011
|
USA
|
T: +1 800 424 4284
|
F: +1 425 481 3895
European Headquarters
|
Via Motta 24
|
6830 Chiasso
|
Switzerland
|
T: +41 91 69769.00
|
F: +41 91 69769.11
Asia-Pacific Headquarters
|
11 Tai Seng Link
|
Singapore
|
534182
|
T: +65 6383 3832
|
F: +65 6383 3830
www.alliedtelesis.com
© 2007 Allied Telesis Inc. All rights reserved. Information in this document is subject to change without notice. All company names, logos, and product designs that are trademarks or registered trademarks are the property of their respective owners.
617-000143 Rev.H