Bosch hdi7052u User Guide

Page of 32
English 2
Before You Begin
Tools and Parts Needed
7 mm Socket Driver w/ 3" extension
Torx (T20)-head screwdriver
Adjustable Wrench
Flathead Screwdriver (1/8" or smaller)
Phillips Head Screwdriver
Parts Included
Conversion Kit Instructions
Conversion Sticker
4 LP Orifices
General Information
Always Provide Adequate 
Gas Supply
This appliance is shipped from the factory for use with natural gas. Use this kit to 
convert the appliance for LP gas use if necessary. Observe the following:
Be sure the range is converted for use with the appropriate gas before using it.
This appliance is designed to operate at a pressure of 10" of water column when 
used with LP gas.  
When checking for proper operation of the regulator, the inlet pressure must be at 
least 1" greater than the operating (manifold) pressure above. When converting 
for LP gas use, the pressure supplied to the regulator must be between 11" and 
14" of water column. See step 2 "Convert Pressure Regulator from 5" to 10" 
W.C.", next page.
The pressure regulator located in the inlet of the range manifold must remain in 
the supply line.
Use a flexible metal appliance connector or rigid pipe to connect the Range to the 
gas supply. The connector should have an I.D. of 1/2" and be 5' in length (Excep-
tion: Maximum connector length in Massachusetts installations is 3'). In Canada, 
the connector must be single wall metal and not longer than 6'.
Preparation
CAUTION: Turn off Gas and Electricity
Before proceeding with the conversion; shut off the gas supply to the appliance 
prior to disconnecting the electrical power.
1. Turn all control knobs to the "OFF" position. 
2. Shut off the outside propane tank gas valve to the range.  
3. Remove range power cord from electrical outlet or turn breaker off at breaker 
box
Procedure
Conversion