Alcatel-Lucent 6850-48 Reference Guide

Page of 3444
BFD Commands
OmniSwitch CLI Reference Guide
September 2009
page 39-9
ip bfd-std l2-hold-timer
Configures the global Layer 2 hold-down (convergence) timer value for the BFD protocol. This command 
specifies the amount of time BFD remains in a hold-down state after a Layer 2 topology change occurs.
ip bfd-std 12-hold-timer l2-holdtimer-interval
Syntax Definitions
l2-holdtimer-interval
The Layer 2 hold-down time interval, in milliseconds. The valid range 
is 100–999.
Defaults
Platforms Supported
OmniSwitch 6400, 6850, 6855, 9000, 9000E
Usage Guidelines
• The global Layer 2 hold-down timer is also configurable at the BFD interface level. Note that configur-
ing the global value with the ip bfd-std l2-hold-timer command does not override the value set for the 
interface using the ip bfd-std interface l2-hold-timer command.
• The global Layer 2 hold-down timer serves as the default value for a BFD interface. The default timer 
value is overridden when a specific value is configured for the interface. 
Examples
-> ip bfd-std l2-holdtimer 500
Release History
Release 6.3.4; command was introduced.
Related Commands
MIB Objects
alaBfdGlobalL2HoldTimer
parameter
default
l2-holdtimer-interval
100 milliseconds
Configures the Layer 2 hold-down timer value for a BFD interface.
Displays the BFD global status and general configuration parameters.