BFD Commands
page 39-8
OmniSwitch CLI Reference Guide
September 2009
ip bfd-std echo interval
Configures the global BFD echo packet time interval. The echo function is available with the asynchro-
nous or demand mode. Echo packets are transmitted to BFD peers to see if they loop back to the peer from 
which they originated.
ip bfd-std echo interval echo-interval
Syntax Definitions
echo-interval
The echo time interval, in milliseconds. The valid range is 100–999.
Defaults
Platforms Supported
OmniSwitch 6400, 6850, 6855, 9000, 9000E
Usage Guidelines
• The echo packet time interval is also configurable at the BFD interface level. Note that configuring the 
global value with the ip bfd-std echo interval command does not override the value set for the inter-
face using the ip bfd-std interface echo interval command.
• The global echo packet time interval serves as the default interval value for a BFD interface. The 
default interval value is overridden when a specific value is configured for the interface. 
Examples
-> ip bfd-std echo interval 500
Release History
Release 6.3.4; command was introduced.
Related Commands
MIB Objects
alaBfdGlobalEchoRxInterval
parameter
default
echo-interval
100 milliseconds
Configures the echo packet time interval for a BFD interface.
Displays the BFD global status and general configuration parameters.