Alcatel-Lucent 6850-48 Reference Guide

Page of 3444
AAA Commands
OmniSwitch CLI Reference Guide
September 2009
page 58-115
show user lockout-setting
Displays the global user lockout settings for the switch. 
show user lockout-setting
Syntax Definitions
N/A
Defaults
N/A
Platforms Supported
OmniSwitch 6400, 6850, 6855, 9000, 9000E
Usage Guidelines
The global lockout settings include parameter values that determine the length of a user observation 
window, the amount of time a locked user remains locked, and the number of failed password login 
attempts allowed. 
Examples
-> show user lockout-setting
Lockout Setting:
Observation window: 30 (minutes)
Duration: 200 (minutes)
Threshold: 20
Release History
Release 6.3.1; command was introduced.
output definitions
Observation window
The amount of time, in minutes, during which the number of failed 
password login attempts are counted. Configured through th
Duration
The amount of time, in minutes, that a locked user account remains 
locked out of the switch. Configured through th
 command.
Threshold
The maximum number of failed password login attempts allowed 
before the user is locked out of the switch. Configured through the