Справочное Руководство для Alcatel-Lucent 6850-48
AAA Commands
OmniSwitch CLI Reference Guide
September 2009
page 58-115
show user lockout-setting
Displays the global user lockout settings for the switch.
show user lockout-setting
Syntax Definitions
N/A
Defaults
N/A
Platforms Supported
OmniSwitch 6400, 6850, 6855, 9000, 9000E
Usage Guidelines
The global lockout settings include parameter values that determine the length of a user observation
window, the amount of time a locked user remains locked, and the number of failed password login
attempts allowed.
window, the amount of time a locked user remains locked, and the number of failed password login
attempts allowed.
Examples
-> show user lockout-setting
Lockout Setting:
Observation window: 30 (minutes)
Duration: 200 (minutes)
Threshold: 20
Release History
Release 6.3.1; command was introduced.
output definitions
Observation window
The amount of time, in minutes, during which the number of failed
password login attempts are counted. Configured through the
password login attempts are counted. Configured through the
Duration
The amount of time, in minutes, that a locked user account remains
locked out of the switch. Configured through the
locked out of the switch. Configured through the
command.
Threshold