Alcatel-Lucent 6850-48 Hardware Manual

Page of 188
OmniSwitch 6850 Series Chassis and Hardware Components
Console Port
OmniSwitch 6850 Series Hardware Users Guide
September 2009
page 2-69
Console Port
The console port, located on the chassis front panel, provides a console connection to the switch and is 
required when logging into the switch for the first time. By default, this RJ-45 connector provides a DTE 
console connection.
Serial Connection Default Settings
The factory default settings for the serial connection are as follows:
Modifying the Serial Connection Settings
The switch’s serial connection defaults are listed above. If you wish to modify the default serial connection 
settings (i.e., baud rate, parity, data bits, and stop bits), refer to the following steps:
Note
You must be connected to the switch via the console port before attempting to change serial connec-
tion settings. Otherwise, an error message will display. 
For switches in a stacked configuration, all changes must be configured before the switches are cabled 
together. In other words, you must configure these settings when each switch is operating as a stand-alone 
unit.
Enter the modify boot parameters command at the CLI prompt. The boot prompt displays:
Boot >
To change the baud rate, enter boot serialbaudrate, followed by the desired baud rate value. Options 
include 1200, 2400, 4800, 9600 (default), 19200, 38400, 57600, 76800, and 115200. For example:
Boot > boot serialbaudrate 19200
Note
Setting the console port to speeds above 9600 baud can cause problems with Zmodem uploads.
To change the parity value, enter boot serialparity, followed by the desired parity value. Options 
include none (default), even, and odd. For example:
Boot > boot serialparity even
To change the data bits (i.e., word size) value, enter boot serialwordsize, followed by the number of 
data bits. Options include 7 and 8 (default). For example:
Boot > boot serialwordsize 7
baud rate
9600
parity
none
data bits (word size)
8
stop bits
1
flow control
none