Quantum atl 7100 Installation Instruction

Page of 68
Chapter 1  Library Specifications and Site Requirements
Library Specifications
6
Quantum|ATL 7100 Series Facilities Planning and Installation Guide
Library Specifications
1
The following tables provide the specifications of the library.
Table 1   Library 
Mechanical 
Specification
Table 2   Library 
Power Specification
Table 3   Library 
Environmental 
Specification
height
56.5 inches (143.5 cm)
width
23.5 inches (59.7 cm)
depth
36.5 inches (92.7 cm)
weight
550 lb. (250 kg) with 96 tape cartridges and 7 tape drives 
installed
AC power rating 
100-120V/200-240V, 7A/3.5A, 50/60 Hz
AC voltage range
90-132 VAC or 180-264 VAC
frequency range
47-63 Hz
temperature
storage — short-term (< 60 days)
storage — long-term (>60 days)
transport
operating
-40 to 151
°
F (-40 to 66
°
C)
 41 to 122
°
F (5 to 50
°
C)
-40 to 151
°
F (-40 to 66
°
C)
 50 to 90
°
F (10 to 32
°
C)