Quantum atl 7100 User Guide
Chapter 2 Operating the Library
Operating Procedures
Operating Procedures
16
Quantum|ATL 7100 Series Library Operator’s Guide
3
After several seconds, verify that SDA shows System On-line.
Placing the Library
Online
Online
2
To place the library online:
1
With the library power applied and the SDA showing
System
Off-line
, press the control panel
STANDBY
button.
2
Verify that System On-line is displayed in the SDA.
Taking the Library
Offline
Offline
2
To take the library offline:
1
With the library power applied and the SDA showing System
On-line, press the control panel
On-line, press the control panel
STANDBY
button.
2
The library robotics will stop after completing the current
command(s). Verify that System Off-line is displayed in the
SDA.
command(s). Verify that System Off-line is displayed in the
SDA.
Removing Power
from the Library
from the Library
2
To remove power from the library:
1
Press the control panel
STANDBY
button. The library robotics
will stop after completing the current command(s). Verify that
System Off-line is displayed in the SDA.
System Off-line is displayed in the SDA.
2
At the rear panel, set the AC power switch to the O (off)
position.
position.
Note:
System On-line
is only displayed if the library power-
up state is configured for
On-line
. Otherwise,
System
Off-line
is displayed.
Caution:
Always leave library power off for at least 15
seconds before turning the power on again.