Quantum atl 7100 User Guide

Page of 78
Chapter 2  Operating the Library
Operating Procedures
16
Quantum|ATL 7100 Series Library Operator’s Guide
3
After several seconds, verify that SDA shows System On-line.
Placing the Library 
Online
2
To place the library online:
1
With the library power applied and the SDA showing 
System 
Off-line
, press the control panel
 STANDBY
 button.
2
Verify that System On-line is displayed in the SDA.
Taking the Library 
Offline
2
To take the library offline:
1
With the library power applied and the SDA showing System 
On-line, press the control panel 
STANDBY
 button.
2
The library robotics will stop after completing the current 
command(s). Verify that System Off-line is displayed in the 
SDA.
Removing Power 
from the Library
2
To remove power from the library:
1
Press the control panel 
STANDBY
 button. The library robotics 
will stop after completing the current command(s). Verify that 
System Off-line is displayed in the SDA.
2
At the rear panel, set the AC power switch to the O (off) 
position.
Note:
System On-line
 is only displayed if the library power-
up state is configured for 
On-line
. Otherwise, 
System 
Off-line
 is displayed.
Caution:
Always leave library power off for at least 15 
seconds before turning the power on again.