Quantum dx100 User Guide
Chapter 4 Troubleshooting
Host Bus Adapter Settings
Host Bus Adapter Settings
100
Quantum DX-Series User’s Guide
•
•
•
JNI™ Fibre
Channel HBA
Channel HBA
4
For the DX-Series system to communicate with the JNI Fibre Channel
HBA, the card must be setup correctly. JNI is configured through
EZ-Fibre. Ensure that the drive mapped check boxes for the DX-Series
system items are selected in the LUN-Level Zoning tab as shown in
Figure 64 JNI Fibre
Channel HBA
Configuration
Channel HBA
Configuration
Must be
checked
checked
Emulex™ Fibre
Channel HBA
Channel HBA
4
For the DX-Series system to communicate with the Emulex Fibre Channel
HBA, the card must be setup correctly. Emulex Fibre Channel HBAs are
configured through the Lightpulse Utility. Ensure that the Automap
function is enabled as shown in
.