INSTALLATION
3-7
3.5.1
Connecting the Network Port Cabling 
You attach unshielded twisted pair segments to the RJ-45 Network Ports 
on the front panel of the MRXI. Since the MRXI utilizes polarity 
detection and correction, the twisted pair connections are not sensitive to 
signal polarity. The network will still function properly with the (+) and 
(–) lines within a pair reversed. Operating in this condition is not 
recommended and if this condition is discovered, the segment should be 
removed from the network and wired correctly by a technician.
1. Connect twisted pair segments to the MRXI Network Port (see Figure 
3-7) by inserting the RJ-45 connector from each twisted pair segment 
into the desired RJ-45 port number on the MRXI.
Figure 3-7
MRXI-24 Network Ports
2. Check that the associated LNK LED for the port is lit. If the LED is 
not lit, perform each of the following steps until it is:
a.
Check that the 10BASE-T device at the other end of the twisted 
pair segment is powered up.
b. Verify that the RJ-45 connector on the twisted pair segment has 
the proper pin-outs as shown in Figure 3-8.
24X
23X
22X 21X 20X 19X
18X
17X 16X
15X 14X 13X
12X
11X 10X  9X
8X
7X
6X
5X
4X
3X
2X
1X
EPIM 1
EPIM 1