Connectivity
SecureStack A2 Installation Guide 
1-3
Stack Connections
The switches have front‐panel RJ45 connectors for connections in a stack configuration. 
The stacking cables used for the connections are standard Category 5 or better UTP cable.
Redundant Power Supply Capability
The SecureStack A2 has power supply redundancy capability when connected to an 
optional external redundant power supply (RPS). If the internal power supply fails, the 
RPS assumes the entire load of the SecureStack A2 without interrupting network traffic. 
The internal power supply and RPS each have their own AC power connection, which 
enables the connection of each power supply to a different AC power circuit for 
additional AC power source redundancy.
Connectivity
The SecureStack A2 connects to Ethernet networks or workstations by means of the fixed 
front panel RJ45 connectors and two fixed fiber‐optic LC connectors. For more 
connectivity information, refer to 
.
Management
Management of the module can be either in‐band or out‐of‐band. In‐band remote 
management is possible using Telnet, the Enterasys NetSight
®
 management application, 
or the WebView application. Out‐of‐band management is provided through the DB9 
Console port connector on the front panel using a VT100 terminal or a VT100 terminal 
emulator.
Switch Configuration Using WebView
Enterasys Networks’ HTTP‐based Web management application (WebView) is an 
intuitive web tool for simple management tasks.
Caution: The A2H123-24 is not PoE-compliant. Do not connect a SecureStack PoE 
Redundant Power System (C2RPS-POE) to the power connector. Otherwise, damage to 
the device may result.
Precaución: El dispositivs A2H123-24 no cumple con el estándar PoE (power over 
ethernet). No conecte una fuente de poder redundante (RPS) SecureStack PoE (C2RPS-