Venting Requirements
WARNING: 
To reduce the risk of fire, this dryer MUST BE 
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
The dryer exhaust must not be connected into any gas vent, 
chimney, wall, ceiling, attic, crawlspace, or a concealed space 
of a building.
If using an existing vent system
Clean lint from the entire length of the system and make sure 
exhaust hood is not plugged with lint. 
Replace any plastic or metal foil vent with rigid or flexible 
heavy metal vent.
Review Vent system chart. Modify existing vent system if 
necessary to achieve the best drying performance. Only rigid 
or flexible metal vent shall be used for exhausting.
If this is a new vent system 
Vent material
Use a heavy metal vent. Do not use plastic or metal foil vent.
4" (102 mm) heavy metal exhaust vent and clamps must be 
used. DURASAFE™ venting products are recommended.
DURASAFE™ vent products can be purchased from your 
dealer or by calling the toll-free number listed on the cover 
of the Dryer User Instructions. For more information, see the 
“Assistance or Service” section of the Dryer User Instructions.
Rigid metal vent
For best drying performance, rigid metal vents are 
recommended.
Rigid metal vent is recommended to avoid crushing and 
kinking.
Flexible metal vent
Flexible metal vents are acceptable only if accessible for 
cleaning.
Flexible metal vent must be fully extended and supported 
when the dryer is in its final location. 
Remove excess flexible metal vent to avoid sagging and 
kinking that may result in reduced airflow and poor 
performance.
Do not install flexible metal vent in enclosed walls, ceilings, 
or floors.
Elbows
45° elbows provide better airflow than 90° elbows.
Clamps
Use clamps to seal all joints. 
Exhaust vent must not be connected or secured with screws 
or other fastening devices that extend into the interior of the 
duct and catch lint. Do not use duct tape.
Exhaust
Recommended hood styles are shown here.
The angled hood style (shown here) is acceptable.
4" (102 mm) heavy metal exhaust vent
WARNING
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death 
or fire.
4"
102 mm
Good
Better
Clamp
A. Louvered hood style
B. Box hood style
     4"
(102 mm)
      4"
(102 mm)
B
A
   4"
(102 mm)
2½"
(64 mm)
The total length of flexible metal vent should not exceed 
7
3
4
 ft (2.4 m).