Amana ngd5500tq Installation Instruction

Page of 32
5
Must include a shutoff valve:
In the U.S.A.:
An individual manual shutoff valve must be installed within 
six (6) feet (1.8 m) of the dryer in accordance with the National 
Fuel Gas Code, ANSI Z223.1.
In Canada:
An individual manual shutoff valve must be installed in 
accordance with the B149.1, Natural Gas and Propane 
Installation Code. It is recommended that an individual 
manual shutoff valve be installed within six (6) feet (1.8 m) 
of the dryer. 
The location should be easy to reach for opening and closing.
Gas supply connection requirements
Use an elbow and a 
³⁄₈" flare x ³⁄₈" NPT adapter fitting 
between the flexible gas connector and the dryer gas pipe, as 
needed to avoid kinking.
Use only pipe-joint compound. Do not use TEFLON
®
 tape.
This dryer must be connected to the gas supply line with a 
listed flexible gas connector that complies with the standard 
for connectors for gas appliances, ANSI Z21.24 or CSA 6.10.
Burner Input Requirements:
Elevations above 10,000 ft (3,048 m):
When installed above 10,000 ft (3,048 m) a 4% reduction of 
the burner Btu rating shown on the model/serial number plate 
is required for each 1,000 ft (305 m) increase in elevation.
Gas supply pressure testing
The dryer must be disconnected from the gas supply piping 
system during pressure testing at pressures greater than 
½ psi.
Dryer Gas Pipe
The gas pipe that comes out through the rear of your dryer 
has a 
³⁄₈" male pipe thread.
A. 
³⁄₈
" NPT dryer pipe
Venting Requirements
WARNING: 
To reduce the risk of fire, this dryer MUST BE 
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
The dryer exhaust must not be connected into any gas vent, 
chimney, wall, ceiling or a concealed space of a building.
If using an existing vent system
Clean lint from the entire length of the system and make sure 
exhaust hood is not plugged with lint. 
Replace any plastic or metal foil vent with rigid or flexible 
heavy metal vent.
Review Vent system chart. Modify existing vent system if 
necessary to achieve the best drying performance.
If this is a new vent system 
Vent material
Use a heavy metal vent. Do not use plastic or metal foil vent.
4" (10.2 cm) heavy metal exhaust vent and clamps must be 
used. DURASAFE™ venting products are recommended.
DURASAFE™ vent products can be purchased from your 
dealer or by calling the toll-free number listed on the cover of 
the Dryer User Instructions. For more information, see the 
“Assistance or Service” section of the Dryer User 
Instructions.
Rigid metal vent
For best drying performance, rigid metal vents are 
recommended.
Rigid metal vent is recommended to avoid crushing and 
kinking.
Flexible metal vent
Flexible metal vents are acceptable only if accessible for 
cleaning.
Flexible metal vent must be fully extended and supported 
when the dryer is in its final location. 
A.
³⁄₈
" flexible gas connector
B.
³⁄₈
" pipe to flare adapter fitting
C.
¹⁄₈
" NPT minimum plugged tapping
D. ½" NPT gas supply line
E. Gas shutoff valve
A
B
E
D
C
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
A
1¼"
(3.2 cm)
9¼"
(23.5 cm)
4" (10.2 cm) heavy metal exhaust vent
WARNING
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
4"
10.2 cm